Four-channel meter I4

4330 4530 

The I4 meter / indicator measures the input physical quantity through four channels using standard sensors ТС, ПТ, АН and АТ and has an alarm output.

Four-channel meter I4 is designed to measure and control from 1 to 4 physical quantities and display the measured values on the built-in digital indicator.
I4 has four independent measuring channels, alarm output (optosimistor (OS), opto-switch (OK) or relay (P)), RS-485 interface with ModBus RTU protocol. The meter has two versions in terms of supply voltage: AC voltage 90..240V (IPI) or DC voltage source 12..24V (IP24).

Appointment

I4 is designed to control temperature, pressure, humidity, flow rate or other physical quantity in several zones at the same time (up to 4) and alarm signaling of any of the monitored parameters going beyond the specified limits (one emergency exit).
I4 is used as an alarm device in ovens, drying chambers in the food, metallurgical and other industries.

General functions and operating modes

  • measurement of temperature (or other physical quantities) of objects using resistance thermocouples (temperature sensors) ТСМ (50М, 100М) and ТСП (50П, 100П, Pt100, Pt500, Pt1000), thermocouples (ТХК, ТХА, ТЖК, etc.), sensors with unified output signal of current АТ (0..5 mA, 0..20 mA, 4..20 mA) and voltage АН (0..1 V, 0..5 V, 0..10 V);
  • formation of the "Emergency" signal (with the possibility of issuing a control signal to the output stage) when the measured physical quantity is outside the specified alarm range, as well as when the input sensor is open or short-circuited;
  • the function of calculating and indicating the square root of the measured value (for example, for measuring the instantaneous flow rate from the sensors АН and АТ);
  • scaling of the scale of measurements;
  • light indication of operating modes;
  • software change of parameters of transformation characteristics (slope, offset);
  • digital filtering of measurements (filter depth - up to 10 measurement periods);
  • change of indication period of measured values;
  • digital calibration of input channels;
  • password protection of parameters;
  • built-in constant voltage source (24V, 100mA) for powering active sensors or for connecting an alarm relay;
  • RS-485 ModBus RTU interface for recording measured values on a PC or for working with a PLC.

 

Additional Information

Number of channels

Input sensor types

,

Number of outputs

Output device types

, ,

RS-485 interface

Supply voltage, V

,

Number of alarm outputs

1

Download

 Passport for I4 (Ukrainian)

 Passport for I4 (Russian)

 

 

Modifications

I [N1] -01 [N2] TS, [N3] PT, [N4] ANx, [N5] ATx / [N6] OK, [N7] P, [N8] OS-2I-RS-485 - IPx - Shch
I2 - 2TS-2I- RS-485 - IPI - Shch
AND 2 2TC 2I RS-485 IPI U
Device type:
I-meter
[N1] - number of measurement channels: 1, 2, 4, 8,
01- alarm output
in a two-channel meter
Number and types of input sensors:
[N2] - number of vehicles
[N3] - number of PTs
[N4] - number of sensors with AN
(AH1 - from 0 to 1 V;
AH2 - from 0 to 10 V;
AH3 - from 0 to 5 V)
[N5] - number of sensors with AT
(AT1 - from 0 to 5 mA;
AT2 - from 0 to 20 mA;
AT3 - from 4 to 20 mA)
Number and types of output devices:
[N6] - number of OK - collector openings
[N7] - number of P - relay
[N8] - number of OS - optosimistor
Number of indicators:
2I- 2 four-digit seven-segment indicators
PC communication interface:
RS-485
Device power supply type:
IPI - power supply from an alternating voltage network with a nominal value of 90 ... 240V
IP24 - power supply from a constant voltage source with a nominal value of 12..24V
Type of shell:
Shch- panel board

Відгуки

Відгуків немає, поки що.

Send review
REGMIK, NVF, PP
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.