Temperature sensors ТСМ-002p, ТСП-002p, ТХА-002p, ТХК-002p, ТЖК-002p, ТП-002p

340 1080 

Temperature sensors ТСМ-002p, ТСП-002p, ТХА-002p, ТХК-002p, ТЖК-002p, ТП-002p group 0 surface transducers are designed to measure the ambient temperature, liquid, gaseous and granular chemically non-aggressive media, as well as the surface of solids in various industries.

SKU: N/A Categories: Tags:

Temperature sensors ТСМ-002p, ТСП-002p, ТХА-002p, ТХК-002p, ТЖК-002p, ТП-002p group 0 surface transducers are designed to measure the ambient temperature, liquid, gaseous and granular chemically non-aggressive media, as well as the surface of solids in various industries.

Temperature is the most common measured parameter, and overheating is one of the most negative factors in the operation of equipment, therefore, there are a huge number of ways and places of using temperature sensors.

The principle of operation of resistance thermocouples is based on a change in the electrical resistance of conductors and semiconductors depending on temperature. The material from which such a sensor is made should have a high temperature coefficient of resistance, possibly a linear dependence of resistance on temperature, good reproducibility of properties and inertness to environmental influences. To the greatest extent, platinum satisfies all of the above properties; slightly less copper.

Thermocouple Are exclusively differential temperature sensors. They generate an electrical signal proportional to the temperature difference between two different points. Therefore, the junction (junction) that we use to measure the required temperature is called the "hot" junction, while the other junction (from which we can not escape) is called the "cold" junction.

Thermal converters (temperature sensors) of group 0 are designed to measure the temperature of the environment, liquid, gaseous and bulk chemically non-aggressive media, as well as the surface of solids in various industries.

Classification of temperature sensors 202 REGMIK by type of measuring (sensing) element

  • resistance thermal converters (thermometers, TS) - copper TSM (50M, 100M), platinum RTD (50P, 100P), thin-film RTD (Pt100, Pt500, Pt1000, Pt2000, Pt10000);
  • thermoelectric thermocouples (thermocouples, PT) - ТХА (К), ТХК (L), ТЖК (J);
  • semiconductor converters - TP (DS18B20).

Main technical characteristics of temperature sensors 202:

  • CHE connection diagram - two-, three-, four-wire;
  • protective reinforcement material - stainless steel 12X18H10T;
  • the design of thermal converters (temperature sensors) - non-separable;
  •  insulation resistance - not less than 100 megohms;
  • tolerance classes - A, B, C (for TSM, TSP), 1, 2 (for THA, THC, TGK).

Additional Information

NSX type

, , ,

Tolerance class

, ,

Mounting part diameter D, mm

, ,

Mounting part length L, mm

, , , , , , , , , , , , ,

Working range of measured temperatures, ° С

, , , ,

Thread type

Thermal inertia index, s

Modifications

TSP - 101 - Pt100 B 3 × 1 - D6 L150 - 40 - 500 M20x1.5 S22 B12 (-40 ... 180)
TSP 1 01 Pt100. B. 3×1 D6 L150 40 500 M20x1.5 S22 B12 (-40…180)
A type:
TSM, TSP, THA, THK, TJK,
TP (semiconductor)
                         
Group:
0 - submersible;
1 - immersed with cable outlets;
2 - superficial;
3 - air.
Vehicle modification:
Designation
modifications
(groups)
Valid values yy
0yy 01, 02, 03, 04, 11, 12
1yy 01, 02, 03, 04, 05, 06, 07, 08
2yy 02, 03, 04, 04r, 05, 05r, 06, 07, 09
3yy 01, 02, 03, 03p, 07
HCX type:
TSP - 10P, 50P, 100P, 1000P, Pt10, Pt50, Pt100, Pt500, Pt1000;
TSM - 10M, 50M, 100M, 500M, 1000M
Tolerance class:
TSP - AA, A, B, C; TSM - A, B, C
Connection diagram of the terminals of the vehicle:
PxN,
Where:
P is the number of pins;
N - number of SE according to Figure 1.1
Mounting part diameter, D, mm according to the dimensional drawing
Mounting part length, L, mm: according to the dimensional drawing
Length of the outer part, Lн, mm: according to the dimensional drawing
Lead length, Lв, mm: according to the dimensional drawing
Connection thread type: according to the dimensional drawing
Union nut size, mm: according to the dimensional drawing
Bayonet size, mm: according to the outline drawing
Temperature range, ° С: according to table 1.10

Download

pdfPassport for sensors ТХА, ТХК, ТЖК

pdfPassport for sensors TSM, TSP

Відгуки

Відгуків немає, поки що.

Send review
REGMIK, NVF, PP
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.