PID controllers with logger function RP2l, RP4l

3240 5420 

Panel PID controllers with a logger function store the measured values of the input physical quantity in the non-volatile memory of the device at specified time intervals. The logger function can be found in one-channel, two-channel, three-channel and four-channel PID controllers with a logger function.

A PID controller with a logger function is designed to measure, control according to the proportional-integral-differential law of the input physical quantity and store its values in the non-volatile memory (up to 10,000 records) of the device at specified time intervals (from 1 to 9999 min) one, two, or four channels.

PID controllers with logger function:

  1. PID controllers with discrete control: RP1l, RP2l, RP4l (types of output devices R, OK, OS);
  2. PID controllers with analog control: RP1l, RP2l (types of output devices AH1, AH2, AH3, AT1, AT2, AT3).

RPhl allows you to perform the following functions:

  • measuring temperature, humidity, pressure (or other physical parameters) of various objects using standard sensors:
    resistance thermoconverters [TC], thermoelectric converters [PT],
    – sensors with a unified current output signal 0..5 mA, 0(4)..20 mA [AT],
    – sensors with a unified output voltage signal 0..1V, 0..10V [AN];
  • moisture measurement based on the psychrometric method using standard vehicles (function of the second channel RP2l, RP4l);
  • display on the built-in LED digital indicators of the current and set temperature values for one of the channels;
  • regulation of temperature (humidity) of objects according to the proportional-integral-derivative (PID) law;
  • the ability to change the set temperature values (setpoints) for the PID controller via two channels;
  • operation in converter mode input value-analog signal (RP1l and RP2l with analog outputs);
  • the ability to automatically adjust the coefficients of the PID controller;
  • data exchange with a personal computer via RS-485 interface;
  • light indication of the device operating mode, generation of the “Error” signal

Modifications of manufacturing PID controllers with logger function RP2l, RP4l

  • number of channels: 2, 4;
  • model with liquid crystal indicator or with four-digit seven-segment indicators;
  • power supply from 220V alternating voltage network and from a 12..24V constant voltage source;
  • types of input signals: UV (universal input), ТС, ПТ, АН and АТ;

 

Additional Information

Number of channels

,

Input sensor types

, ,

Output device types

, , , , , , , ,

Number of indicators

RS-485 interface

Supply voltage, V

,

Download

Passport for RP2l with discrete control

Application examples

Modifications

Modifications of panel meters and regulators with logger function
T [N1] -01l [N2] TS, [N3] PT, [N4] ANx, [N5] ATx / [N6] OK, [N7] P, [N8] OS, [N9] ANx, [N10] ATx -2И-RS-485 -ИПх-Щ
RP1l - 1TS / 1AN2-2I-RS-485-IPI-Shch
RP 1 l 1TS 1АН2 2I RS-485 IPI U
Device type:
I-meter
RD - two-position regulator
RP-PID controller
[N1] - number of measurement / regulation channels
1- I1, RD1 and RP1 (with analog and digital outputs)
2- I2, RD2 and RP2 (with analog and digital outputs)
3- only RD3
4- I4, RD4 and RP4 (only with discrete outputs)
8- I8
01- alarm output for two-channel meter
The logger function allows you to save in the non-volatile memory of the device
measured values (up to 10,000 records) with a specified time interval (from 1 to 9999 min).
Number and types of input sensors:
[N2] - number of vehicles
[N3] - number of PTs
[N4] - number of sensors with AN
(AH1 - from 0 to 1 V;
AH2 - from 0 to 10 V;
AH3 - from 0 to 5 V)
[N5] - number of sensors with AT
(AT1 - from 0 to 5 mA;
AT2 - from 0 to 20 mA;
AT3 - from 4 to 20 mA)
Number and types of output devices:
[N6] - number of OK - collector openings
[N7] - number of P - relay
[N8] - number of OS - optosimistor
[N9] - number of voltage outputs АН
(AH1 - from 0 to 1 V;
AH2 - from 0 to 10 V;
AH3 - from 0 to 5 V)
[N10] - number of AT current outputs
(AT1 - from 0 to 5 mA;
AT2 - from 0 to 20 mA;
AT3 - from 4 to 20 mA)
Number of indicators:
2I- 2 four-digit seven-segment indicators
PC communication interface:
RS-485 - added to all switchboards with logger function
Device power supply type:
IPI- power supply from an alternating voltage network with a nominal value of 90 ... 240V
IP24 - power supply from a constant voltage source with a nominal value of 12..24V
Type of shell:
Shch- panel board

Відгуки

Відгуків немає, поки що.

Send review
REGMIK, NVF, PP
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.