PID controller for controlling gate valves and three-position valves RP1-3

Price on request

PID controller RP1-3 is designed to control a shut-off and control valve (KZR) or a three-way valve without taking into account its position according to the PID or pulse law, and also allows you to adjust the input physical quantity according to the proportional-integral-differential (PID) law in the “heater- fridge". DIN-rail housing. It is possible to manufacture a device of non-standard modification with outputs K, OC, OK or OC and powered from a DC / AC voltage source with a nominal value of 12..24V. The cost and timing of manufacturing non-standard modifications of devices, check with manager.

PID-regulator for controlling gate valves and three-position valves RP1-3 is designed to receive and convert signals from resistance thermocouples (RT), thermoelectric transducers (TT) and sensors with unified output signal of current (AT) and voltage (V) into temperature values (or other physical quantity) and display them on built-in digital indicators with simultaneous regulation of temperature of objects by proportional-integral-differential (PID) law.

RP1-3 allows you to control a shut-off and control valve (KZR) or a three-way valve without taking into account its position according to the PID or pulse law.

The device automatically controls the state of the sensors, the finding of the measured temperature in the set measurement range.

The main functions of RP1-3:

  • measurement of temperature, humidity, pressure (or other physical parameters)
    different objects on one or two channels using standard sensors:
    resistance thermoconverters [TC], thermoelectric converters [PT],
    sensors with a unified current output signal 0..5 mA, 0 (4) .. 20 mA [AT] and
    voltage 0..1V, 0..10V [AN];
  • display on the built-in LED digital indicators of the current and set values
    temperature;
  • regulation of a physical quantity by proportional-integral
    differential (PID) law;
  • control of the shut-off and control valve (KZR) or three-way valve without taking into account it
    provisions for PID or impulse law;
  • maintaining the temperature of the object according to the proportional-integral-differential (PID) law in
    system "heater-refrigerator";
  • the ability to change the set temperature values (setpoints) for the PID controller;
  • the ability to automatically adjust the coefficients of the PID controller;
  • data exchange with a personal computer via RS-485 interface;
  • two power modifications: from an alternating voltage network with a nominal value of 220V or from a constant voltage source with a nominal value of 12..24V;
  • light indication of the operating mode of the device, formation of the “Error” signal.
Number of channels

Input sensor types

Number of outputs

Output device types

, , ,

RS-485 interface

Supply voltage, V

,

Characteristics

Input device types
Input primary converter
Measurement range, ° С
Modification
Sensor code
Type
NSH
TS according to DSTU 2858-94
01
TCM 50 W = 1.4260
50M
-50..+200
02
TCM 50 W = 1.4280
50M
-50..+200
03
TSP 50 W = 1.3850
Pt50
-50..+600
04
TSP 50 W = 1.3910
50P
-50..+600
05
TCM 100 W = 1.4260
100M
-50..+200
06
TCM 100 W = 1.4280
100M
-50..+200
07
TSP 100 W = 1.3850
Pt100
-50..+600
08
TSP 100 W = 1.3910
100P
-50..+600
09
TSP 46 W = 1.3910
group 21
-50..+600
71
TSP 500 W = 1.3850
Pt500
-50..+600
72
TSP 1000 W = 1.3850
Pt1000
-50..+600
TS according to DSTU 2837-94
10
THK
L
-30..+600
11
TXA
K
-50..+1200
12
TJK
J
-30..+850
13
CCI 10
S
0..+1750
15
TPR
B
+200..+1800
16
TVR
A-1
0..+2500
AN
21
Voltage АН1 (0-1V)
User defined
22
Voltage AH2 (0-10V)
23
Voltage AH3 (0-5V)
AT
31
AT1 current (0-5 mA)
User defined
32
AT2 current (0-20 mA)
33
AT3 current (4-20 mA)
Output device types
Output device
Load capacity
Electromagnetic relay (P)
5A 220V
Triac optocoupler (OS)
100mA 220V
Transistor optocoupler (OK)
150mA 80V
Power triac (C)
2 A 220V
Main technical characteristics of the temperature controller
Description of characteristics
Value
Rated supply voltage, V
220AC
12..24 DC
Supply voltage tolerance, %
± 10
Power consumption, W
6
Set value (setpoint), ° С
-50..2500
Hysteresis, ° С
0..1300
Lower limit of the tolerance field, ° С
-50..2500
The upper limit of the tolerance field, ° С
-50..2500
Conversion characteristic shift, ° С
-99,9..999,9
Cold junction temperature correction, ° С
-99,9..99,9
Conversion slope
0,001..9,999
Digital filter
0,1..99,9
Averaging time, number of measurement periods
0..9
Output device activation delay, s
0..255
Delay of turning off the output device, s
0..255

Download

Passport for the regulator RP1-3-D

Відгуки

Відгуків немає, поки що.

Send review
REGMIK, NVF, PP
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.