Two-channel humidity and temperature meter I4-2DVT

$129

The two-channel humidity and temperature meter I4-2DVT is designed to measure, control and display on built-in digital indicators humidity and temperature from two digital sensors DVTc and has an alarm output.

Two-channel humidity and temperature meter I4-2DVT is designed to receive and convert signals from two digital humidity and temperature sensors and display the obtained values on built-in digital indicators.
I4-2 can be used to create climate control systems via RS-485 interface together with PLCs of various manufacturers, as well as data acquisition systems on PC.

General functions and operation modes of I4-2DVT:

  • joint operation with two combined humidity sensors with digital output type DVT-001ts, -002ts, -101ts, -302ts, -303ts;
  • the ability to work with humidity and temperature sensors SHT1x, SHT2x, DHT11, DHT22;
  • indication of the value of humidity, temperature and dew point;
  • digital settings of the temperature and humidity meter;
  • the ability to work in the temperature meter, humidity meter, temperature and humidity meter;
  • light indication of operating modes;
  • software change of parameters of transformation characteristics (slope, offset);
  • digital filtering of measurements (filter depth - up to 10 periods of temperature and humidity measurements);
  • alarm signaling (with signal output to an external actuator) when any measured parameter exceeds the specified limits;
  • changing the indication period of the measured value;
  • password protection of parameters;
  • RS-485 Modbus RTU interface.

Additional Information

Number of channels

Input sensor types

Number of outputs

Output device types

, ,

RS-485 interface

Supply voltage, V

,

Download

Passport for I4 2DVT

Application examples

Modifications

T [N1] [N2] DVTts / [N3] ANx, [N4] ATx, [N5] P, [N6] OK, [N7] OC- RS485 - IPx - Shch
I2 - 1DVTts / 2AN2-2I- RS485 - IPI - U
AND 2 1DVTts 2АН2 RS485 IPI U
T-device type:
AND- meter
RD-two-position regulator
RP- PID controller
[N1] - number of channels for measuring / regulating humidity and temperature
2 (for I, RD and RP)
4 (for I)
8 (for I)
[N2] - number of input digital temperature and humidity_sensors (DVTts)
1 (for I, RD and RP)
2 (for I)
4 (for I)
Number and types of output devices:
[N3] - number of analog outputs AH
(AH1 - 0 to 1 V;
AH2 - from 0 to 10 V;
AH3 - from 0 to 5 V) only for I2 and RP2
[N4] - number of analog outputs AT
(AT1 - from 0 to 5 mA;
AT2 - 0 to 20 mA;
AT3 - from 4 to 20 mA) only for I2 and RP2
[N5] - number of Р - relays (only for РД2 and РП2)
[N6] - number of OK - manifold openings (only for RD2 and RP2)
[N7] - number of OS - optosimistor (only for RD2 and RP2)
PC communication interface:
RS485
Device power supply type:
IPI- AC power supply with nominal 90 ... 240V
IP24- power supply from a constant voltage source rated 12..24V
Type of shell:
U- panel board

Відгуки

Відгуків немає, поки що.

Send review
REGMIK, NVF, PP
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.